Bilge Alarm Investigation

Alex Johnson

10 February 2026

Summary

Investigated intermittent bilge alarm and found corroded wiring and a sticking float switch. Temporary fix applied with a plan for a more permanent solution after quote approval.

Areas Inspected

Engine condition

OK

Alex to keep an eye on the engine condition over the next week.

Hull inspection

OK

Electrical systems

INTERVENTION REQUIRED
  • Corroded wiring at bilge pump
  • Float switch sticking

Found corroded wiring at bilge pump and float switch sticking; cleaned contacts and freed switch.

Actions Done On Site

Actions for Service Provider

Actions for Client

Quote Required

Re-wiring and replacing float switch for bilge pump

Item Quantity Priority
Tinned cable for bilge pump re-wire 1 High
New float switch for bilge pump 1 High

Invoice Items

Call-out service and temporary fix performed

Item Quantity
Call-out service and labour 1
Tinned copper cable used as temporary fix 1