Investigated issues with the charger tripping RCD. Temporary fix put in place while further actions are scheduled after quote approval.
Monitor over the next week as discussed with John.
Checked and found adequate for current load.
RCD is warm indicating potential nuisance tripping under EV load.
Temporary fix implemented; further action to follow.
Resealed isolator box with a cable grommet.
Inspection needed for isolator and cable tails as part of further action.
Need for Type B RCBO and inspections after RCD nuisance.
| Item | Quantity | Priority |
|---|---|---|
| Type B RCBO for EV circuit | 1 | High |
| Inspection of EV isolator | 1 | Medium |
| Inspection of tails | 1 | Medium |
Work completed including call-out and resealing.
| Item | Quantity |
|---|---|
| Call-out and labour for resealing isolator box with cable grommet | 1 |